AbleStage/Help

Venue load-in check

A short safety routine before doors — confirm AbleStage can reach the rig and kill it.

When you arrive at a venue, before you trust anything else, run a load-in check. It's the lighting equivalent of a soundcheck: make sure AbleStage can talk to the rig, and confirm a blackout actually turns the lights off. Five minutes, before doors.

This page describes the workflow inside AbleStage. If the venue is running its own console from your handoff, the LD does an equivalent check on their side.

The three steps

Connect to the network

If you're driving the rig directly, plug into the venue's lighting network and click Connect to Art-Net. AbleStage will announce itself and listen for nodes. If nothing answers, check:

  • Wired vs. Wi-Fi (use wired).
  • Your network card's IP — it must be on the same subnet as the Art-Net node.
  • Firewall on UDP 6454.

Send a blackout

Click Send blackout to drop every fixture to zero. This proves AbleStage's signal is reaching the rig and the desk is honoring it.

If the rig doesn't go dark:

  • The venue console may be in a mode that ignores external input.
  • Some fixtures hold their last value in their own memory; check the desk's grand-master.

Confirm the room went dark

Stand somewhere you can see every fixture and click Confirm dark. This logs the calibration so you have a paper trail of when the rig last responded — useful if something goes sideways during the show.

Why bother?

The point isn't paranoia, it's the inverse: once you've passed this check, you know your stop button works. That's worth five minutes.

On this page